Call Now: (484) 545-8015
From a replacement breaker to a whole-home battery, here is what we do and where permits change the answer.
We handle everyday electrical repairs anywhere we serve, and we install the equipment that needs a permit where we can pull one. This page covers both, and it is plain about the two cities where permitted work is off the table for us right now.
Plumbing and Electrical
Fixture replacement, wiring repair, and breaker replacement, anywhere we serve.
We handle basic electrical work throughout our service area: replacing fixtures, repairing wiring, and replacing breakers. In general, that means any job that does not require a permit.
Panel changeouts, panel upgrades, generators, and whole-home batteries need a permit, and we pull it where we can.
Some projects require a permit, including panel changeouts, panel upgrades, generator installations, and whole-home battery installations. Where we can pull the permit, we do.
Allentown and Bethlehem require a master electrician's license, which we do not have on staff.
The cities of Allentown and Bethlehem require a master electrician’s license for permitted electrical work. Bethlehem accepts only its own master license or one from a city it has a reciprocity agreement with, and Allentown licenses its own electricians. We do not currently have anyone on staff who holds a master electrician’s license, so we cannot take on permitted projects inside those two cities. Everywhere else we serve, we can pull the permit. That includes Easton, where we hold the city’s residential contractor license, which covers permitted work on one- and two-family dwellings. Basic work that does not need a permit, like fixture and breaker replacement, is not affected.
Square D QO panels as our standard, and SPAN smart panels when you want to see and control every circuit.
For panel changeouts, we install Square D QO panels, built around Square D’s Qwik-Open breaker mechanism. If you want more insight and control, we also install SPAN smart panels. A SPAN panel replaces your existing breaker box and adds monitoring and control for every individual circuit, which makes it a good fit for homes with solar, a battery, or an EV charger. We also install Square D QO sub-panels when your home needs more circuits.
Surge protection at your panel and at your heating and cooling equipment, so one bad surge does not take out the electronics in your home.
A power surge is a brief spike in voltage. Lightning, utility switching, and large motors cycling on and off can all cause one, and today’s homes are full of electronics that a spike can damage, from furnace and air conditioner control boards to appliances, TVs, and computers. We install surge protection at three levels: one device at your panel that protects the whole home, smaller devices at your heating and cooling equipment, and surge-protected power strips for the electronics you plug in.
Since the 2020 National Electrical Code, major modifications to electric service on a home need a surge protective device.
Section 230.67 of the National Electrical Code requires a surge protective device on every service that supplies a home. It must be a Type 1 or Type 2 device, either built into the service equipment or installed immediately next to it, and it is required when service equipment is replaced. That includes switching your main disconnect to new equipment, which is what a generator transfer switch or a battery system can do. Pennsylvania’s Uniform Construction Code uses the 2020 NEC, and the state’s 2021 code update took effect on January 1, 2026. The rule exists because homes now depend on sensitive electronics, including safety equipment such as smoke alarms, AFCI breakers, and GFCI outlets.
For us, that means every panel changeout comes with surge protection, and so does every generator or battery installation that changes your main disconnect. If your panel and main disconnect stay as they are, the code does not require it, but we can add it.
The Intermatic IG2280-IM protects every circuit in the home from one device at the panel.
We install the Intermatic IG2280-IM, a Type 2 surge protective device for 120/240 volt single-phase homes. It mounts in a metal enclosure beside your panel and connects to your service, so it protects every circuit in the house, including the ones that feed your HVAC equipment, appliances, and electronics. It has six modes of protection, which covers every pairing of the two hot wires, the neutral, and the ground. Its protection modules are replaceable, and it has status indicators so you can see that it is working. Intermatic backs it with a 10-year product warranty and a $25,000 connected equipment warranty, subject to Intermatic’s terms.
A smaller Intermatic AG3000 at the equipment adds a second layer where the costly electronics are.
Heating and cooling equipment is some of the most expensive electronics in a home. Furnaces, air conditioners, heat pumps, and ductless systems all depend on circuit boards and electronic controls that a surge can damage. For that equipment, we install the Intermatic AG3000, a small surge protective device made for HVAC equipment. It connects at the equipment’s disconnect or directly to the air handler or furnace, it sits in a weatherproof, UV-resistant enclosure, and a green light shows that its protection is active. Intermatic backs it with a 3-year, $7,500 connected equipment warranty, subject to Intermatic’s terms.
The device at the panel takes the big hit, the device at the equipment protects what is left, and a surge-protected power strip covers what you plug in.
A surge protector at the panel stops most of a surge as it enters the home, but some energy can still travel through the wiring beyond it. A second device at the furnace or air conditioner catches what remains before it reaches the circuit boards, and a Type 3 device, such as a surge-protected power strip at the outlet, protects the computers, TVs, and other electronics you plug in. Surges can also start inside your home, such as when a compressor or motor switches on and off, and a device at the equipment sits closest to them. Protection at the service, at the equipment, and at the outlet working together is the approach the electrical industry recommends, and it is how we protect a home. Some appliances and equipment also have a built-in surge component, called a Type 4. It cannot be serviced or replaced, so think of it as a last line of defense, not a substitute for the layers above.
No surge protector can promise to survive a direct lightning strike, but protecting the panel and the equipment gives your electronics the best odds.
Home charging on a circuit sized for your charger and your panel.
We install EV chargers. A charger needs a dedicated circuit and enough spare capacity in your panel, so we look at your panel first and tell you whether it can carry the load or needs an upgrade. A charger install is permitted work, so the city limits above apply.
For panels with ample capacity, or for customers who want a panel upgrade, we can install any charger that is compatible with your vehicle.
Otherwise, we install a SPAN panel with a SPAN Drive EV charger, which is designed to work with it. This combination lets us add a charger to your existing electrical service without a service upgrade. SPAN’s PowerUp software throttles power to the charger and other large loads as needed to keep your home’s total demand under 80% of its rated capacity.
A SPAN panel still needs a permit, like any other panel, but it reduces the need for the additional permits that a service upgrade would require.
We install Briggs & Stratton PowerProtect+ standby generators, built to start your air conditioner and keep your home running through an outage.
We are a Briggs & Stratton dealer and install its PowerProtect+ DX home standby generators in 18kW, 22kW, and 26kW, along with the PowerProtect DX 13kW. We can also service Generac standby generators. A standby generator is permitted work, so the city limits above apply. A generator can also back up a home battery during an outage long enough to drain it, and its transfer switch works the same way it does in a home without a battery.
Every PowerProtect+ model is built to start a 5-ton air conditioner.
Starting a large motor, like an air conditioner compressor or a well pump, takes much more power than keeping it running. Briggs & Stratton says every PowerProtect+ generator is engineered to start a 5-ton air conditioner, so you do not have to buy a bigger, more expensive generator just for motor starting power. The engine is a commercial-grade Vanguard. The compact 13kW PowerProtect DX has 37 kVA of motor starting power, which Briggs & Stratton says easily handles large appliances.
Front-facing exhaust keeps fumes away from the house and gives us more options for where the generator goes.
PowerProtect+ generators vent out the front, away from the house. Briggs & Stratton says they are the only standby generators with front-facing exhaust, a design that is safer and also gives us more flexibility in where we place the unit. The PowerProtect DX 13kW has a front exhaust as well.
Installed by a Briggs & Stratton dealer, your generator is covered for 10 years.
Every PowerProtect+ generator comes with a seven-year standard warranty that covers parts, labor, and travel. Briggs & Stratton also offers a dealer-exclusive (DX) 10-year warranty on generators a dealer installs. We are a dealer, so every generator we install is covered for 10 years.
Check on your generator from your phone, and let us diagnose problems remotely.
PowerProtect+ generators come ready for EnergyTrak remote monitoring. The app is free to download, and the monitoring service is a paid subscription, which is $99 a year. It shows whether your generator is ready to run, running, or needs service, tells you when utility power goes out and comes back, and tracks run time during an outage. It also lets us troubleshoot and diagnose problems remotely, and its cellular connection keeps it online even if your home Wi-Fi goes down.
A soft starter lets your air conditioner or heat pump start on a generator without needing a bigger generator.
If you want your air conditioner or heat pump to run on a generator, the best setup includes a soft starter. A standard central air conditioner or heat pump uses a “bang start”: the compressor goes from off to full speed at once and pulls a large surge of current for a moment. On a generator, that surge is often what decides whether the system starts. A soft starter ramps the compressor up gradually instead.
We exclusively install the Micro-Air EasyStart Flex on standard central air conditioners and heat pumps. Micro-Air says it reduces start-up current by up to 75%, which lets a system run on a generator, an inverter, or limited power when it otherwise might not start, and that it works with two-stage compressors and heat pumps. Micro-Air also says it lets you run more appliances on a smaller generator, and a gentler start means less strain on the compressor, less start-up noise, and less flicker in your lights.
The transfer switch connects your generator to your home, and the code decides where it goes and what comes with it.
A standby generator connects to your home through a transfer switch, which moves your house from the utility to the generator and keeps generator power off the utility’s lines. Under the 2020 National Electrical Code, a service-rated transfer switch that becomes your main disconnect counts as new service equipment, so it brings two requirements with it: an emergency disconnect outside the house, and a whole-home surge protective device.
A service-rated transfer switch mounted outside the house covers the first requirement on its own, because it serves as your outdoor disconnect. If the transfer switch has to go inside, we install a separate disconnect outside and mark it as the emergency disconnect, so first responders can cut power to the house without going in. Either way, we add the surge protective device described above.
FranklinWH batteries that back up your home, work with solar, and shift when you buy power.
We install FranklinWH whole-home batteries. The aPower 2 stores 15 kWh and delivers 10 kW continuously. The aGate controller manages power flow between your solar, battery, home, and the grid, and switches to backup power automatically at the first sign of an outage.
Adding a battery changes your service equipment, so the same two code rules apply as with a generator: an emergency disconnect outside the house and a whole-home surge protective device. We include both on our battery installs.
A whole-home battery backs up your home quietly, with or without solar panels.
A whole-home battery is an alternative to a standby generator. It switches to backup power automatically when the power goes out, it is quieter than a generator, and you do not need solar panels to have one. You charge it from the grid, and if your utility offers a time-of-use plan, you can charge it when electricity is cheapest, which is covered below. A battery holds a fixed amount of energy, while a generator keeps running as long as it has fuel, so we size the battery around what you need to keep running and for how long. Some homes pair a battery with a generator.
For ultimate protection during long outages, pair the battery with a standby generator. If an outage lasts long enough to drain the battery and your solar panels cannot keep up, the generator’s transfer switch moves your home onto the generator, the same way it does in a home without a battery.
A battery stores your midday solar surplus for the evening and can keep your panels working during an outage.
If you have solar panels, a battery can store the midday surplus and use it after sunset instead of sending it to the grid. How much that saves depends on how the utility credits your exports, which is covered below. The aPower 2 is AC-coupled, so it can usually be added to solar you already have, and we check your inverter and electrical panel first to confirm. We do not install solar panels, but we can add a battery to a system you already have.
A required safety function keeps your panels dark when the grid is down, and a battery is the safe way around it.
Utility lines stay dead while crews repair them. If your solar inverter kept pushing power into those lines, it could hurt the people working on them. So the interconnection standards, IEEE 1547 and UL 1741, require grid-tied inverters to detect an outage and shut down. That is why a solar home goes dark in a blackout, even on a bright afternoon. It is not a defect, it is a required safety feature, and we will never bypass or disable it. Net metering credits do not help either, because banked credits are a billing record on the utility’s side, not stored power.
A battery gets around this safely through intentional islanding. When the grid fails, the FranklinWH aGate opens the connection to the utility, so nothing your home produces can flow out to the lines, and it powers your backup circuits from the battery. With the home isolated, the battery system supplies the voltage and frequency your solar inverter needs, so your panels can keep producing and recharging the battery during the day. When the utility is stable again, the system reconnects. Backup is limited to what the battery can deliver, and in a storm that also blocks the sun you run on the charge the battery already holds, which is why we set an outage reserve first.
Prefer to watch? This short video from DangLab TV explains how solar panels become a whole-house power system.
Your solar exports earn credit at the full retail rate, which is why a battery adds less to your bill than you might expect.
Under Pennsylvania net metering, the utility credits each kilowatt-hour you send to the grid at the full retail rate, and any surplus carries forward month to month at that rate. Whatever is left at the end of May is paid out at the lower Price to Compare. In effect, the grid works as a battery that costs you nothing and remembers for a year, so on a standard rate a home battery adds little to your bill savings and its main value is backup. If you switch to a third-party electricity supplier after signing up for net metering, you stop receiving credit for excess generation from your utility.
Higher prices from 2 to 6 p.m. in summer and 4 to 8 p.m. in winter, lower prices the rest of the time.
PPL’s net metering time-of-use plan splits the day into on-peak and off-peak hours. In summer (June 1 to November 30), on-peak is 2 to 6 p.m. on weekdays. In winter (December 1 to May 31), on-peak is 4 to 8 p.m. on weekdays. Everything else is off-peak, including nights, weekends, and select holidays.
Off-peak electricity costs less than the standard Price to Compare, and on-peak electricity costs more. At the time of writing, PPL lists residential rates of 17.542 cents per kWh on-peak and 12.140 cents off-peak. The rates and peak hours change every June 1 and December 1. Excess solar is banked at the rate in effect when you produced it, so a kilowatt-hour you export during the peak window is credited at the higher price. Most residential net metering customers can join, there are no enrollment or cancellation fees, and you must buy your electricity from PPL rather than a third-party supplier.
Met-Ed's optional rate has three price periods and is open to net metering customers.
Met-Ed’s time-of-use pricing is an optional rate for smart-metered residential customers who are not in its Customer Assistance Program. On-peak is 2 to 9 p.m. on weekdays, super off-peak is 11 p.m. to 6 a.m. every day, and off-peak is every other hour. The periods do not change with the season.
Each price is set as a multiple of Met-Ed’s Price to Compare, so on-peak electricity costs more than the standard rate and both off-peak periods cost less. The plan covers only the electricity supply portion of your bill, not delivery. Most net metering customers can join, but customers on budget billing cannot. There is no cost to enroll, and you can leave at any time without penalty, but you cannot rejoin for 12 months. It is a default service rate, so it does not apply if you buy your electricity from a third-party supplier.
A straight look at what shifting power around is worth over a year.
The gap between the two rates is about 5.4 cents per kWh. A FranklinWH aPower 2 holds 15 kWh and is about 90% efficient from grid to load. If you charged it fully every off-peak hour and emptied it into every weekday peak window, you would save about 55 cents a day, or roughly $135 a year. That is the ceiling. Most homes do not use 13 kWh in a four-hour window, and a home that uses 6 kWh in the peak window saves closer to $60 a year. Rate shifting alone will not pay for a battery. A battery earns its place the first time the grid fails, which is why we set the schedule around outages first. These figures use PPL’s rates and a four-hour peak window. Met-Ed’s weekday peak window is seven hours and its rates differ, so for a Met-Ed home we work out the numbers from your bill.
We set an outage reserve first, then charge around the peak window.
FranklinWH systems run in several modes, including Self-Consumption, Emergency Backup, Storm Hedge, which charges the battery to 100% when the National Weather Service issues a severe weather alert, and Time of Use, which charges in off-peak hours and discharges in peak hours. We set the reserve first, based on what you need to keep running and for how long, and let the savings come from whatever is left. Charging from the grid at night costs about the same as charging from your own solar at midday, because every kilowatt-hour you keep is one you did not export for a credit at the off-peak rate, so the timing of the charge matters more than the source. On PPL in summer, we charge from solar in the morning and early afternoon and discharge into your home from 2 to 6 p.m. In winter, solar fills what it can and the grid tops the battery up overnight so it is full when the 4 to 8 p.m. window opens. On Met-Ed, we charge from solar and during the 11 p.m. to 6 a.m. super off-peak window, and discharge into your home from 2 to 9 p.m. on weekdays. We review the schedule whenever your utility changes its rates.
The 30% federal credit for homeowner-owned solar and batteries does not apply to new installs.
The 30% federal Residential Clean Energy Credit ended for expenditures made after December 31, 2025, and it covered batteries too. Many websites still advertise it. A battery installed now should be judged on backup value and bill savings alone. Ask your tax professional whether any other incentive applies to you.
Straight answers about what we repair, what we install, and what we leave to others.
Projects such as panel changeouts, panel upgrades, generator installations, and whole-home battery installations need a permit. Basic work like replacing a fixture, repairing wiring, or replacing a breaker generally does not.
Not at this time. Those cities require a master electrician’s license for permitted work, and we do not have one on staff. We can still help with basic electrical work there that does not need a permit, and we can pull permits everywhere else we serve.
For panel changeouts, we install Square D QO panels. If you want circuit-by-circuit monitoring and control, we also install SPAN smart panels. We install Square D QO sub-panels when your home needs more circuits.
The electrical code requires a surge protective device whenever a home’s electrical service is installed or its service equipment is replaced. That includes a panel changeout and any generator or battery installation that changes your main disconnect, and we include one on those jobs. If your panel and main disconnect stay as they are, the code does not require it, but we recommend it, because one surge can damage electronics throughout the house.
For computers, TVs, and other sensitive electronics, yes. A device at your panel and a plug-in protector at the outlet work together, the same way the panel device and an HVAC surge protector do.
Yes. We install the Intermatic AG3000, a small surge protective device made for HVAC equipment, at the equipment’s disconnect or at the unit. Paired with the Intermatic IG2280-IM at your panel, it gives you two layers of protection, and a surge-protected power strip at the outlet adds a third.
Yes. We are a Briggs & Stratton dealer, and we can also service Generac. A generator is permitted work, so we cannot install one inside Allentown or Bethlehem.
Briggs & Stratton PowerProtect+ generators are built to start a 5-ton air conditioner, vent their exhaust away from your home, carry a 10-year warranty when a dealer installs them, and come ready for EnergyTrak remote monitoring. As a Briggs & Stratton dealer, we install the PowerProtect+ DX line and the PowerProtect DX 13kW.
Yes, and we recommend a soft starter. A standard central air conditioner or heat pump pulls a large surge of current when it starts, and that surge is the hardest thing for a generator to handle. We install the Micro-Air EasyStart Flex on standard central air conditioners and heat pumps to soften the start, which Micro-Air says cuts start-up current by up to 75%.
It depends on what you want to run. A single FranklinWH aPower 2 delivers 10 kW continuously, so we size the system to your loads, add batteries when you need more power or longer run time, and can set up Smart Circuits to shed less important loads and stretch the battery.
Not on their own. Grid-tied inverters are required to shut down when the grid fails, as a safety rule for utility workers. With a battery system that isolates your home from the grid, your panels can keep running and recharging the battery during the day.
No. A battery charges from the grid, so it works in any home. It backs up your essential circuits when the power goes out, and on a time-of-use plan you can charge it when electricity is cheapest. If you do have solar, the battery can store your midday surplus too.
Usually, yes. The FranklinWH aPower 2 is AC-coupled, which is built to work with an existing solar system. We look at your inverter and your electrical panel first to confirm.
A little. Pennsylvania net metering already credits your solar exports at the full retail rate, so the grid works like a free battery. Shifting power on PPL’s time-of-use plan with a 15 kWh battery is worth about $60 to $135 a year. A battery’s main value is backup power.
It depends on when you use power and when your panels produce it. There are no enrollment or cancellation fees, but you must buy your electricity from PPL rather than a third-party supplier. We can look at your bills and tell you what we see.
It depends on when you use power and when your panels produce it. Met-Ed’s weekday peak runs seven hours, so a single battery often covers only part of it. There is no cost to enroll and you can leave at any time, but you cannot rejoin for 12 months, so we look at your bills first.
Not for homeowner-owned solar or batteries. The credit ended for expenditures made after December 31, 2025. Ask your tax professional whether any other incentive applies to you.
It is a FranklinWH setting that watches National Weather Service alerts. When a severe weather alert is issued, it charges the battery to 100%, then returns to normal when the alert ends.
Evaluations, designs, and quotes for upgrades and new installations are free. Repairs and service calls are billed at our standard repair rates, or at our after-hours rates for service outside regular hours. Financing is available through Wisetack and can be viewed directly from your quote. Additionally, we are part of the National Energy Improvement Fund (NEIF), which issues loans to homeowners for energy-based home improvements with low interest financing. Financing is subject to credit approval.
We serve Nazareth, PA and the surrounding Lehigh Valley communities. See our Service Area page for the list of towns.
Tell us what you need, and we will tell you plainly whether it is a job we take on.
Not sure whether your job is one we do? Call (484) 545-8015 or request service online. Check our Service Area page to see the towns we serve, and visit Recent Projects to see if we have worked in your neighborhood.